Definition

Blood

Blood is a body fluid with its main function is to transport important substances such as oxygen (O2) and carbon dioxide (CO2). Blood also provides tissues with nutrients, removes waste product, and contains a variety of substances aimed at the immune system defending the body from infection. Endocrine hormones are also distributed through the blood.

Blood Gas

Oxygen is needed for most of the metablolic reactions and carbon dioxide in the blood serves to regulate the balance of acids and bases / alkalis and body respiration .

pH

Scale that measures the acid and alkaline of solution or fluids.

O2 – Oxygen

CO2 – Carbon dioxide

HCO3 – Bicarbonate

Introduction

Blood makes up about 8% of our total body weight, i.e., a person weighing 70 kg (154 lbs) has about 6 liters (10.5 pints) of blood.

The heart pumps blood at a rate of 5.5 L/minute (9.7pints/minute)

Blood is a medium of transport to and from the cells for:

  • exchange of food molecules and waste products
  • exchange of oxygen and carbon dioxide
  • regulation of acid/base balance
  • protection against infection
  • regulation of body temperature


Diagram above shows the respiratory cycle that occurs in the human body and the content of oxygen and carbon dioxide gas which is found in the lungs and blood..

Acid-Base Balance In Blood

pH or acidity of the blood depends on the degree of ions H+ and it is controlled by 3 ways / mechanism; which is the mechanism of buffer / buffer chemistry, respiration and kidney function.

Changes of pH blood occurs through 2 ways :

  1. Metabolic
    Changes in the content of bicarbonate [HCO3] caused by metabolic disorders.
  2. Respiratory
    Changes in CO2 partial pressure (pCO2) caused by respiratory disorders.

Changes in pCO2 and / or HCO3 will lead to changes in blood pH. Acidosis (pH drops below normal) will occur when pCO2 increases and / or bicarbonate decreased, whereas alkalosis occurs when otherwise.

In the blood, the level of acidity is measured in pH units, the value of 1 (acid) to 14 (base / alkaline) with normal or neutral value of 7.. Most processes in the body run normally at physiological pH of 7.4 .

To ensure the pH remains within the normal level, acid base balance in the blood needs to be controlled precisely as little changes in pH can lead to serious effect to the organ or system.

Acid base balance in blood are controlled through 3 ways / mechanism :

  1. Excessive acid are excreted by renal, mostly in the form of ammonia.
  2. Buffer in the blood serves as a protector against pH changes that occur suddenly. Bicarbonate is the most important buffer in blood.
  3. Excretion of CO2 in the lungs
    Production of CO2 gas from metabolic processes will be carried by the blood to the lungs for excretion.

Test For Blood Gas

How is it used?

Blood gas measurements are used to evaluate patients oxygenation and acid/base status. They are typically ordered if there are worsening symptoms of

  • an acid/base imbalance,
  • difficulty of breathing, or
  • shortness of breath.

Blood gases may be ordered along with other tests, such as

  • Electrolytes test to determine if an electrolyte imbalance is present,
  • Glucose test to evaluate blood sugar concentrations,
  • Urea and Creatinine tests to evaluate kidney function.

For patients who undergo supplemental oxygen therapy, blood gases may be used to monitor the effectiveness of that treatment.

When the test is performed?

Blood gas tests are performed for patients with symptoms of :

  • difficulty breathing,
  • shortness of breath,
  • nausea
  • vomiting

Blood gas measurements may be ordered for patients with :

  • Head or neck trauma, injuries that may affect breathing.
  • Renal disease and respiration disorders.

What was measured?

The measured parameters are :

  • Partial pressure of oxygen (pO2)
  • Partial pressure of carbon dioxide (pCO2)
  • pH
  • Bicarbonate (HCO3)
  • Oxygen saturation (O2)

Procedure For Blood Sampling

  1. Preparation for patientsThe respiratory condition of the patient should be stable.
    • The patient should preferably be in a steady state of ventilation before and during the collection of blood sample.
    • The patient should be informed about the procedure in order to avoid unnecessary anxiety. If the patient hyperventilation due to anxiety, for example pH and blood gases may be affected.
  2. Tube usedSyringe with anti-coagulant

  3. Sample typeThere are two types of sample for blood gas analysis :
    • Arterial blood gasThe most preferred and recommended type of blood for pH/blood gas analysis
      – It gives the best information about the oxygen uptake in the lungs and oxygen transport.


      Picture shown the blood sample taken from arterial blood vessel


      Picture shown the location of arterial blood vessels

    • Venous Blood GasNot generally recommended for blood gas analysis

      – Should not be used to evaluate oxygen status
      – Can be used to reflect acid-base status (pH, pCO2, HCO3).

  4. Procedure of sample collection
    • Indicate time of arterial or venous puncture in the request form.
    • Use a 1 ml disposable syringe
    • If using regular syringe, rinse it by sucking heparin (5000 units per ml) into the syringe and expel excess heparin solution from the syringe.
    • If using alcohol to clean the venipuncture site, allow the alcohol to dry completely.
    • Draw 1 ml of blood
    • Invert the syringe upward and expel all air bubbles.
    • Mix well by rolling between palms for 5 seconds
  5. Specimen Transportation to the laboratory
    • Syringe is placed in a specimen plastic bag/ container containing water and ice. Make sure the blood in the syringe is immersed completely in ice water
    • The sample must reach the laboratory for analysis in 30 minutes after drawing of blood.
  6. Analysis of blood gas Analysis of blood gas is performed on analyser with electrode principle.


    Example of blood gas analyser

Normal Range

Parameter

Arterial Blood Gas

Venous Blood Gas

pH

7.35-7.45

7.33-7.43

pCO2 (mmHg)

35-45

38-51

     pO2 (mmHg)

71-104

30-71

    O2 sat (%)

95-100 %

60-85

HCO3 (mmol/L)

22-29

22-29

Table shown normal range for blood gas result.

pH result

Bicarbonate result

PCO2 result

Condition

Common causes

Less than 7.4

Low

Low

Metabolic acidosis

Kidney failure, shock, diabetic ketoacidosis

Greater than 7.4

High

High

Metabolic alkalosis

Chronic vomiting, low blood potassium

Less than 7.4

High

High

Respiratory acidosis

Lung diseases such as pneumonia,

Greater than 7.4

Low

Low

Respiratory alkalosis

Hyperventilation, pain, anxiety

 

Combinations of results that may be seen in certain conditions are summarized in above table

Last Reviewed : 5 December 2013
Writer : Rohaznida bt. Baharudin

 

Artikel Berkaitan

Ecstasy

What is Ecstasy? It is a drug under the Amphetamine-Type

Post-Lingual Hearing Loss

Post-Lingual Hearing Loss is a deafness which develops after the acquisition of speech and language. It can occur gradually or with sudden onset hearing loss.

Behaviour

Introduction Behaviour problems or ‘challenging behaviours’ and adaptive skill deficits

ALAMAT

Bahagian Pendidikan Kesihatan,
Kementerian Kesihatan Malaysia,
Aras 1-3, Blok E10, Kompleks E,
Kompleks Pentadbiran Kerajaan Persekutuan,
62590 Putrajaya, Malaysia.

TALIAN AM :   +603 8000 8000

FAKS :   +603 8888 6200

EMEL :   myhealth@moh.gov.my

BILANGAN PENGUNJUNG : 227,767,451

TARIKH AKHIR KEMASINI :
2024-07-16 15:32:21

PAPARAN TERBAIK   Paparan terbaik menggunakan pelayar Google Chrome Version 57.0, Mozilla Firefox Version 52.0 dengan resolusi 1366 x 768px

Hakcipta Terpelihara ©2005-2022 Bahagian Pendidikan Kesihatan, Kementerian Kesihatan Malaysia